This page lists ClearBlade IoT Core requirements and related information.
Regions and versions
Cloud regions
Only these cloud regions are available: us-central1
, europe-west1
, and asia-east1
.
Transport
...
layer security (TLS)
ClearBlade IoT Core requires TLS version 1.2 or higher. For more guidance on TLS, see the Minimum standards for TLS clients section in Disabling SSLv3 and RC4.
...
MQTT version 3.1.1 is required.
The following These features are not supported:
MQTT QoS 2
Arbitrary MQTT topics and subscriptions. For topic requirements, see the connecting devices using MQTT section
Last Will will and Testament testament (LWT)
Retained messages
Persistent sessions
...
ClearBlade IoT Core supports HTTP 1.1 only (not 2.0).
Permitted characters and size requirements
Registries, device identifiers, and their associated fields are limited to certain characters. These fields are also limited in size (either length or byte size).The following table lists the
Each resource’s permitted characters and sizes
...
Resource | Limitations |
---|---|
| |
| |
| |
| |
Subfolders* |
|
*Subfolders refer to the eventNotificationConfigs.subfolderMatches
device registry field. It is used when matching MQTT or HTTP subfolders to a Cloud Pub/Sub topic.