Separate from the keep-alive interval, ClearBlade IoT Core’s idle time limit is 20 minutes. Based on this, a client connection will automatically be terminated if the client doesn't send any messages for 20 minutes, even if the keep-alive interval is longer. If a keep-alive value isn't supplied, the default idle timeout of 20 minutes still takes effect.
Error Codes
The ClearBlade MQTT broker honors the following MQTT 3.1.1 error codes.
Value | Return Code Response | Description |
---|---|---|
0 | 0x00 Connection Accepted | Connection accepted |
1 | 0x01 Connection Refused, unacceptable protocol version | The Server does not support the level of the MQTT protocol requested by the Client |
2 | 0x02 Connection Refused, identifier rejected | The Client identifier is correct UTF-8 but not allowed by the Server. This can be caused by a duplicate |
3 | 0x03 Connection Refused, Server unavailable | The Network Connection has been made but the MQTT service is unavailable |
4 | 0x04 Connection Refused, bad user name or password | The data in the user name or password is malformed |
13 | 0x13 | All other events for connect, disconnect, publish and subscribe |